A. Purpose. This section establishes the development standards and site requirements for uses in the industrial zones. The standards and rules are established to provide flexibility in project design, prevent fire danger, provide adequate access and circulation, reduce incompatibilities, and prevent overloading of infrastructure due to the impacts of development.

B. Explanation of Table. Development standards are listed down the left column of the table and the industrial zones are identified across the top row. The matrix cells contain the requirements of each zone. The footnotes identify particular requirements applicable to a specific use, standard, or zone.

TABLE 2: DEVELOPMENT STANDARDS IN INDUSTRIAL ZONES

Development Standards

MLIP

L-I

H-I

Minimum lot size

NR

NR

NR

Maximum lot size

NR

NR

NR

Maximum building height

50'1

50'1

NR2

Front yard setback3

NR

NR

NR

Exterior side yard setback3

NR

NR

NR

Interior side yard setback3

NR

NR

NR

Rear yard setback3

NR

NR

NR

Landscaping requirements

None

Chapter 18.57

Chapter 18.57

Minimum landscaped buffer along residential zoned property

15'

15'

25'

Buffer requirements

Signage

Chapter 18.58

Chapter 18.58

Chapter 18.58

Outside storage

Section 18.40.110

Section 18.40.110

Section 18.40.110

Fencing requirements

Section 18.40.120

Section 18.40.120

Section 18.40.120

Parking requirements

Chapter 18.54

Chapter 18.54

Chapter 18.54

Containment within a building

Section 18.40.070

Section18.40.070

NR

NR = No requirement for the zone. Other regulations may apply.

Footnotes for Table 2:

1.The Hearing Examiner may allow buildings or structures to be erected to an additional height after a public hearing and examination of the location and upon due proof to the satisfaction of the Hearing Examiner that such additional height will not be detrimental to the surrounding properties.

2.Subject to the provisions of Chapter 18.52 entitled “Grant County Airport Zoning.”

3. Setbacks: A. Within the setback area shown on Table 2, no building or structure (as defined in Section 18.03.040) shall be allowed, except flagpoles, street furniture, transit shelters, signage, fencing, slope stability structures, and improvements less than thirty inches (30") above grade, including decks, patios, walks, and driveways. Some of these structures and improvements require a permit.

B. The setbacks shown in the table are zoning setbacks. Larger setbacks may be required by the State Building Code, State Fire Code, sight distance requirements, or landscaping requirements (Chapter 18.57).

(Ord. 2949, 4/14/20; Ord. 2929, 8/13/19; Ord. 2459, 5/12/09; Ord. 2144, 12/9/03)